Saving Energy Through Reducing Extraction
Variable air volume (VAV) is a method of reducing the volume of extracted air.
This is achieved through monitoring the face velocity and actuating a volume control damper on the outlet of the fume cupboard. As the air velocity increases over a set point (usually 0.4 or 0.5m/s) the damper will close to reduce the volume extracted.
"Customers can reduce air volumes by up to 85%"
This means that whilst the fume cupboard sashes are closed, less heated/cooled air is being extracted out of the room, reducing your energy bills and improving the ambient temperature for the end users.
"Annual saving of $36,000!"
Saving Energy Through Reducing Extraction
Auto-sash is another option aimed at improving safety and reducing energy bills.
Through the use of a PIR absence detector, the sash will automatically close when the user is not present. Combined with a VAV system this will then reduce the volume extracted.
The sash is driven by a motor located in the top of the fume cupboard.
To avoid collisions, a light-curtain detects any obstacles such as equipment or limbs in the path of the sash.
Note: Auto-Sash is an additional option to the VAV fume cupboard.
Specification & Compliance
The K8 complies with BS EN14175 standards for containment. We offer standard widths from 1000mm to 2000mm, or fully bespoke dimensions to fit your facility.
- Smooth radiused front profile for improved aerodynamics
- Type tested to BS EN14175 @ 0.30m/sec to 0.50m/sec
- 316 grade stainless steel front cill (Polypropylene available)
- Inner chamber: 6mm Trespa TopLab BASE
- 16mm Trespa TopLab BASE bunded base
- High performance removable back baffles
- TEL AFA4000/E tactile airflow monitor, VAV Controller and alarm
- 250mm ECON VAV Damper
- 6mm toughened glass sash on twin stainless steel cables
Standard Dimensions
| Dimension | Value |
|---|---|
| Standard Widths | 1000, 1200, 1500, 1800, 2000mm |
| Standard Depth | 900mm |
| Standard Height | 2400mm |
| Sash Type | Vertical Rising |
| Lighting | LED Low Energy |
Note: All electricals (Alarm, Light, Double Sockets) come pre-wired to a junction box for easy installation.
Optional Extras
Tailor your K8 Fume Cupboard to your specific laboratory requirements with our range of upgrades.
Ventilated Storage
Integrated storage for chemicals beneath the unit.
VAV Systems
Variable Air Volume control for energy efficiency.
Auto-Sash
Automatic sash closure for safety and energy saving.
Fire Trace
Automated fire suppression systems.
Material Upgrades
Polypropylene or Stainless Steel chambers.
Epoxy Worktops
Cast epoxy resin for extreme chemical resistance.
Installations
See our K8 VAV fume cupboards installed in laboratories across the UK.
K8 VAV Installation
Integrated Storage
TEL Alarm Panel
Trusted by leading organisations across the UK
Trusted by Laboratories Nationwide
For over 25 years, we've been designing and manufacturing fume cupboards for universities, schools, and industrial laboratories across the UK.
Ready to Upgrade Your Laboratory?
Contact our team to discuss your fume cupboard requirements. We offer free site surveys and bespoke solutions.
The Process
We handle everything in-house in North Yorkshire, ensuring you aren't just buying an off-the-shelf solution.
1. Design
Every project starts in Solidworks. We issue fully dimensioned drawings for your approval before we cut a single piece of material.
2. Build
Manufactured in our modern North Yorkshire factory. Our team of skilled engineers and fabricators ensure the highest standards.
3. Install
Our own fitters deliver and install your fume cupboard anywhere in the UK, ensuring seamless integration.
Downloads & Resources
Industrial Fume Cupboard FAQs
Common questions about our industrial and research fume cupboards
BS EN 14175 is the European standard for fume cupboard performance, covering containment, airflow, and safety. All our industrial fume cupboards are type-tested to this standard, ensuring they provide reliable protection for laboratory personnel working with hazardous substances.
Our K8 series industrial fume cupboards are available in standard widths of 1000mm, 1200mm, 1500mm, 1800mm, and 2000mm. We also manufacture bespoke sizes to fit your specific laboratory requirements.
Yes, all our K8 series fume cupboards can be configured with VAV technology. VAV systems automatically adjust extraction rates based on sash position, reducing energy consumption by up to 70% compared to constant volume systems.
We offer a range of worktop materials including Trespa TopLab BASE (our standard), stainless steel, polypropylene, and epoxy resin. The choice depends on the chemicals and processes you'll be working with.
Yes, we offer full turnkey installation across the UK. Our experienced team handles delivery, positioning, connection to extraction systems, and commissioning. We also provide LEV testing and certification.
As every fume cupboard is built to order in our North Yorkshire factory, typical lead times are 6-8 weeks from order confirmation. We can accommodate urgent requirements where possible.
All our fume cupboards come fitted with a TEL AFA4000 airflow monitor as standard. This provides visual and audible alarms if airflow drops below safe levels, with options for BMS integration.
Yes, our K8 Walk-In fume cupboard is designed for larger equipment and processes. It features full-height access with the same BS EN 14175 containment performance as our standard models.
Ready to Configure Your K8?
Whether you need a single unit or a full laboratory fit-out, our team in North Yorkshire is ready to help.